User instructions for the ABI-system 100
0124
Seitenansicht 0
1 2 3 4 5 6 ... 23 24

Inhaltsverzeichnis

Seite 1

User instructions for the ABI-system 1000124

Seite 2 - TM, Windows® 7

10Assignment of the cuffs to the extremities.:Check the correct assignment of the cuffs to the extremities by seperate measure-ments of left arm, righ

Seite 3

11Measurement tab:Performed measurements can be viewed in the “Measurements” tab.If several measurements have already been carried out, select the des

Seite 4

12Click on one of the oscillation profiles to enlarge the view of the selected profile.The “Pulse level over time” tab shows the oscillation curve ove

Seite 5

13Preparing for a measurementThe measurement must be performed on a patient who is lying down in order ensure equal blood pressure among all limbs.The

Seite 6

14Taking a measurementIn order to add a new patient in the ABI software, select the “New” button in the “Patient” tab. “Name” and “Patient no.” are ob

Seite 7

15Systole (mmHg)Diastole (mmHg)The decreasing cuff pressure will be displayed during the measuring phase. By this time (at the latest) all four limbs

Seite 8

16If all of the values were correctly displayed after carrying out the second set of measurements, click the button “Save measurement” and then “Back”

Seite 9

17The times above the measurement value columns indicate the time of measurement (1st and 2nd measurement).Cancelling a measurementA measurement can b

Seite 10

18Technical dataMeasurement method: oscillometricMeasurement range: 40 – 240 mmHgCuff pressure: 0 – 300 mmHgDisplay: LCDOperating conditions:Ambient t

Seite 11

19Technical testing procedureA) Function testingFunction testing of the device can only be performed on human subjects or using a suitable simulator.B

Seite 12

2User instructions for the ABI-system 1001 ABI-system 1002 CA04 cuffs (for upper arms)2 CL04 cuffs (for legs)1 ABI-system 100 software 1 USB cab

Seite 13

20Medical Electrical Equipment needs special precautions regarding EMC and needs to be installed and put into ser-vice according the EMC information p

Seite 14

21150 kHz to 80 MHzd = 1,2 P0,120,381,23,812Guidance and manufacturer’s declaration – electromagnetic immunityThe boso unit is intended for use in

Seite 16

23Your notes:

Seite 17

BOSCH + SOHN GmbH u. Co. KGBahnhofstraße64•72417Jungingen•GermanyPhone:+49(7477)9275-0•Fax:+49(7477)1021Internet:www.boso.de•e-Ma

Seite 18

3Explanation of symbols and user controlsSTART keyPressthiskeytostartanABImeasurement.All4cuffswillbeinated.STOP keyPress this key to

Seite 19

4Read the user instructions!Explanation of symbols usedClass II deviceProtection level against electric shock: Type BFUSB 2.0ConnectionThe CE symbol i

Seite 20

5Introductory informationYour boso ABI-system 100 is an innovation on the market for blood pressure mea-surement. It represents an easy way to determi

Seite 21

6ABIThe systolic blood pressure values of a person’s arms and legs need to be mea-sured in order to determine the ABI value. The blood pressure measur

Seite 22 - Your notes:

7Installing the network versionFirstly you need to install the Firebird database server locally on the server by clicking the button “Installiere Fire

Seite 23

8Installing the USB connection cable• Connect the USB connection cable to a free USB port on your PC.• WINDOWS automatically detects the USB-cableData

Seite 24 - BOSCH + SOHN GmbH u. Co. KG

9Entering doctor’s data:The personal data of the doctor in charge can be entered in the “Doctor” tab which is then used as the basis for the printout